Villa MK II
Unique single roll tile gives a smart, sleek finish to any style of roof. Available in 5 colours and compatible with all Scott Dry Fix Accessories.
Technical Data
Designation: EN490 - IL - 31 - RF - 300X405 - 5.51
- Maximum Pitch 54° without special fixing (see under fixing)
- Minimum Pitch 22.5° 17.5° *
- Minimum Head lap 75mm 100mm
- Maximum Gauge 344mm 319mm
* The performance of Scott concrete roof tiles has been verified by independent wind tunnel testing. In low exposure situations and/or for short rafter lengths, it may be possible to lay tiles below the quoted minimum pitch. Call Scott Customer Services for advice.
- Size of Tile (overall): 419mm x 334mm
- Hanging Length: 405mm
- Nominal Cover Width: 300mm
- Tile Weight: 5.15kg
- Profile Depth: 31mm
- Nail Hole Diameter: 5 - 8mm
- Nail Hole Position: 30 + or - 5mm from the top of the tile
- Weight of Tiling (Approx.)
- Headlap 75mm 100mm
- Weight/mē 50kg 54kg
- Net Covering Capacity
- Headlap 75mm 100mm
- Tiles/mē 9.7 10.4
- Net Batten Length
- Headlap 75mm 100mm
- Length/mē 2.9m 3.1m
Recommended Batten Size
Minimum 38mm x 25mm for rafters not exceeding 600mm span. Battens to be secured with round wire or cut wire nails conforming to BS 5534.
Eave: Standard tile with eave filler unit
Verge Bedded Verge
Right Hand: Standard Tile
Left Hand: Left Hand Verge Tile
Dry Verge: Scott Rooverge available in uPVC interlocking units left and right hand with stop end eaves units and ridge capping. (See accessories page)
Undercloak: 150mm wide fibre reinforced cement strip.
Fixing (minimum):
All perimeter tiles to be mechanically fixed in accordance with BS 5534.
17.5° - 29° Perimeter tiles to be nailed or clipped.
30° - 44° Each tile in alternate courses to be nailed or clipped in a chequer board pattern.
45° - 54° Each tile to be nailed or clipped.
55° and over: each tile to be nailed and clipped.
Nails to be 40mm x 2.65mm Aluminium. Reference AA.
Clips to be Scott Villa Mk II standard tile clip. Reference AS.
Verge: Villa MK II verge clip reference AS.
Eave: Villa MK II eave clip reference AS.
It is recommended that windloading calculations be carried out for all pitches, and ground conditions to ascertain if more onerous fixings are required.
Valley: Open metal valley
Abutment: Cover flashing, Secret gutter
Ridge Wet Fix: Half Round, butt jointed, 455mm long
Ridge Dry Fix: Scott Roovent Dry Ridge System
Hip: Third Round Ridge butt jointed 455mm Long
Mono Ridge: Universal type, butt jointed 455mm long
To view our terms & conditions of sale and supply of good please click here.
The colours and textures displayed on this website are as accurate as can be reproduced. We recommend referring to samples (available on request)
